IPC Fixture Pressure Requirements (Table 604.3)
IPC Table 604.3 required pressure at fixture outlets for proper operation.
Introduction
IPC Table 604.3 specifies the minimum pressure required at fixture outlets for proper operation. These values are critical for pressure analysis - the available pressure must exceed the required pressure at the most hydraulically remote fixture.
IPC Table 604.3 - Required Pressure at Fixture Outlets
| Fixture | Type | Flow Rate (GPM) | Required Pressure (psi) |
|---|---|---|---|
| Water closet | Blow out, flushometer valve | 25 | 45 |
| Water closet | Siphonic, flushometer valve | 25 | 35 |
| Water closet | Tank type | 3 | 20 |
| Urinal | Flushometer valve | 12 | 25 |
| Urinal | Tank type | 3 | 20 |
| Shower | Thermostatic / balanced | 3 | 20 |
| Bathtub | Thermostatic / balanced | 4 | 20 |
| Lavatory | Faucet | 2 | 8 |
| Sink | Faucet | 3 | 8 |
| Service sink | Faucet | 3 | 8 |
| Kitchen sink | Faucet | 3 | 8 |
| Drinking fountain | Faucet | 0.75 | 8 |
| Hose bibb | Faucet | 5 | 8 |
Notes
- • Flushometer valve fixtures require significantly higher pressures (35-45 psi) than tank-type fixtures (20 psi).
- • These pressures must be available AT the fixture outlet, not at the building entrance.
- • Pressure analysis adds static head, friction losses, and meter losses to these values.
- • Plumbing Booster uses these values automatically in IPC pressure analysis.
Related Articles
Pressure Analysis Methodology
Pressure analysis determines whether the available municipal supply pressure is sufficient to deliver adequate pressure at every fixture. Here is how Plumbing Booster performs this analysis.
Booster Pump Sizing Guide
Booster pump sizing starts with pressure deficiency analysis and ends with a pump duty point. Plumbing Booster supports six pump types with computed friction mode and source-linked duty points.
IPC Pipe Sizing Guide
Step-by-step explanation of the IPC table-based pipe sizing method, from WSFU summation through flow conversion to final pipe selection using Table E104.1.
Want to try these calculations yourself?
Download Plumbing Booster Free Trial →Ready to design smarter?
Start your 28-day free trial today. No credit card required.