Water Heaters

Water Heater Sizing Guide

Water heater sizing determines the storage capacity and recovery rate needed to meet peak hot water demand. Here is the ASHRAE-based methodology Plumbing Booster uses.

Plumbing Booster water heater sizing screen

Introduction

Water heater sizing ensures that a building has sufficient hot water storage and recovery capacity to meet peak demand. Undersized heaters run out of hot water; oversized heaters waste energy. Plumbing Booster uses ASHRAE Handbook methodologies with multiple sizing tables to provide accurate sizing recommendations.

Methodology

Plumbing Booster supports multiple ASHRAE and ASPE sizing methods: **ASPE 2015 Methods:** 1. **ASPE Method 1: Average Hourly Demand** - Fixture-based average demand calculation. 2. **ASPE Method 2: Occupancy Type (Multifamily)** - Multifamily demand by occupancy class (LMH). **ASHRAE 2019 Service Water Heating Methods:** 3. **ASHRAE Table 6** - Peak hour and daily demand. 4. **ASHRAE Table 7 (Apartments)** - Apartment sizing by LMH classification. 5. **ASHRAE Example 1 Table 8** - Design time (simplified method). 6. **ASHRAE Example 1 Table 9** - More accurate method. 7. **ASHRAE Table 10** - Fixture-based method. 8. **ASHRAE Tables 11-12** - Food service sizing. 9. **ASHRAE Table 13** - Industrial wash fountains and showers. 10. **ASHRAE Table 14** - Ready-mix concrete plant. 11. **ASHRAE Table 16** - Hot-water demand in fixture units. 12. **ASHRAE Table 17** - Preliminary demand. For each method: - Input: Building type, fixture counts, hot water temperature, usage patterns - Output: Required storage volume (gallons or liters) and recovery rate (GPH or L/h) - The software selects the appropriate table based on the chosen method and building parameters.

Storage vs Recovery

Water heater capacity has two components: - **Storage volume**: The tank capacity in gallons/liters. Larger storage handles peak draws without running out. - **Recovery rate**: How fast the heater can reheat water, in GPH (gallons per hour) or L/h. Higher recovery means less storage needed. There is a trade-off: high-recovery + low-storage or low-recovery + high-storage both work. The ASHRAE tables optimize this balance for each building type.

How Plumbing Booster Automates It

The Water Heaters module: 1. Select sizing method (ASPE Method 1 or 2, or ASHRAE Tables 6, 7, 8, 9, 10, 11-12, 13, 14, 16, or 17). 2. Enter building parameters (type, fixtures, temperature). 3. The software calculates required storage and recovery. 4. For catalog mode, it matches heaters from the built-in catalog (AO Smith and others) with brand policy (any/prefer/require), hard constraints (recirculation, installation, venting, pressure, temperature, gas/electrical, connections, dimensions, certifications), and scoring weights (oversize, footprint, weight, maintenance, cost, efficiency). 5. For generic mode, it uses B2 auto-staging (choose k units <= maxUnits meeting envelope, optional N+1 redundancy). 6. The Summary page shows sizing results, selected heaters, and compliance status.

Want to try these calculations yourself?

Download Plumbing Booster Free Trial →